Recherche
  • Huawei OptiXaccess EA5801E-GP16 pc

    Huawei OptiXaccess EA5801E-GP16

    Compact and low-density box-shaped OLT.

Overview

  • Overview
  • Features
  • Specifications
Huawei OptiXaccess EA5801E-GP16

Huawei OptiXaccess EA5801E-GP16

Huawei OptiXaccess EA5801E-GP16 is a box-shaped Optical Line Terminal (OLT) with Gigabit Passive Optical Network (GPON) access, supporting both Passive Optical LAN (POL) and Fiber To The Home (FTTH) solutions. It carries all services over a single fiber network, considerably simplifying network architecture as well as reducing Operating Expense (OPEX).

Only requiring a remarkably compact installation space of just 1U, the device is applicable to Access Point (AP) convergence on a small scale. As such, OptiXaccess EA5801E-GP16 is well-suited to lightweight deployment in enterprises, with a single OLT meeting the service-bearing requirements for the entire campus.

End-to-end Networking

Adaptable to Diverse Scenarios

Requires only 1U installation space for small-scale AP convergence, meeting service-bearing requirements for an enterprise or campus with just a single OLT

Flexible Installation

Rapid Deployment and Installation

Suitable for installation in both indoor and outdoor cabinets, the OLT can withstand high temperatures, saving both manpower and cabinet space

Specifications

Parameters Huawei OptiXaccess EA5801E-GP16
Dimensions (H x W x D) Excluding mounting ears: 43.6 x 442 x 220 mm
Including IEC mounting ears: 43.6 x 482.6 x 220 mm
Including ETSI mounting ears: 43.6 x 535 x 220 mm
Maximum Fully-Loaded Weight (DC) 4.2 kg
Maximum Fully-Loaded Weight (AC) 4.6 kg
Power Supply Mode DC power supply (dual backup)
AC power supply (dual backup)
Working Voltage Range DC power supply: –38.4 V to –72 V
AC power supply: 100–240 V
Rated Voltage DC power supply: –48/–60 V
AC power supply
Maximum Input Current DC power supply: 6 A
AC power supply: 2.5 A
Ambient Temperature –40°C to +65°C
The device can start up at temperatures as low as –25°C.
Note:
65°C refers to the highest temperature measured at the air intake vent of a service subrack.
Ambient Humidity 5–95% RH
Atmospheric Pressure 70–106 kPa
Altitude < 4000 m. The air density varies with the altitude and will affect the heat dissipation of the device. Therefore, the working environment temperature of the device varies with the altitude.
System Switching Capacity 140 Gbit/s
MAC Addresses 32,768
Access ONT 1024
IPv4 Routing Table 8192
IPv6 Routing Table 4096
ARP Table 16,384
Bit Error Rate (BER) in Full Load A BER smaller than 10 e-7 for a port that transmits data in full load.
10 GE/GE Upstream Ports 4
Service Ports 16 GPON
Power Consumption Static power consumption: 55 W
Typical power consumption: 95 W
Maximum power consumption: 140 W
Note: The power consumption of a product is tested in the following conditions
• Static power consumption: 25°C, no optical module in optical ports, and no service.
• Typical power consumption: 25°C, 4 x 10 GE upstream ports, 16 x GPON ports on the user side, full services, and maximum traffic.
• Maximum power consumption: 65°C, 4 x 10 GE upstream ports, 16 x GPON ports on the user side, full services, and maximum traffic.

TOP