Huawei OptiXaccess EA5801E-GP16
Compact and low-density box-shaped OLT.
Productos, soluciones and servicios para los negocios
Huawei OptiXaccess EA5801E-GP16
Huawei OptiXaccess EA5801E-GP16 is a box-shaped Optical Line Terminal (OLT) with Gigabit Passive Optical Network (GPON) access, supporting both Passive Optical LAN (POL) and Fiber To The Home (FTTH) solutions. It carries all services over a single fiber network, considerably simplifying network architecture as well as reducing Operating Expense (OPEX).
Only requiring a remarkably compact installation space of just 1U, the device is applicable to Access Point (AP) convergence on a small scale. As such, OptiXaccess EA5801E-GP16 is well-suited to lightweight deployment in enterprises, with a single OLT meeting the service-bearing requirements for the entire campus.
Adaptable to Diverse Scenarios
Rapid Deployment and Installation
Specifications
Parameters | Huawei OptiXaccess EA5801E-GP16 |
Dimensions (H x W x D) | Excluding mounting ears: 43.6 x 442 x 220 mm Including IEC mounting ears: 43.6 x 482.6 x 220 mm Including ETSI mounting ears: 43.6 x 535 x 220 mm |
Maximum Fully-Loaded Weight (DC) | 4.2 kg |
Maximum Fully-Loaded Weight (AC) | 4.6 kg |
Power Supply Mode | DC power supply (dual backup) AC power supply (dual backup) |
Working Voltage Range | DC power supply: –38.4 V to –72 V AC power supply: 100–240 V |
Rated Voltage | DC power supply: –48/–60 V AC power supply |
Maximum Input Current | DC power supply: 6 A AC power supply: 2.5 A |
Ambient Temperature | –40°C to +65°C The device can start up at temperatures as low as –25°C. Note: 65°C refers to the highest temperature measured at the air intake vent of a service subrack. |
Ambient Humidity | 5–95% RH |
Atmospheric Pressure | 70–106 kPa |
Altitude | < 4000 m. The air density varies with the altitude and will affect the heat dissipation of the device. Therefore, the working environment temperature of the device varies with the altitude. |
System Switching Capacity | 140 Gbit/s |
MAC Addresses | 32,768 |
Access ONT | 1024 |
IPv4 Routing Table | 8192 |
IPv6 Routing Table | 4096 |
ARP Table | 16,384 |
Bit Error Rate (BER) in Full Load | A BER smaller than 10 e-7 for a port that transmits data in full load. |
10 GE/GE Upstream Ports | 4 |
Service Ports | 16 GPON |
Power Consumption | Static power consumption: 55 W Typical power consumption: 95 W Maximum power consumption: 140 W Note: The power consumption of a product is tested in the following conditions • Static power consumption: 25°C, no optical module in optical ports, and no service. • Typical power consumption: 25°C, 4 x 10 GE upstream ports, 16 x GPON ports on the user side, full services, and maximum traffic. • Maximum power consumption: 65°C, 4 x 10 GE upstream ports, 16 x GPON ports on the user side, full services, and maximum traffic. |