CloudEngine 6800 Series
Data Center Switches
Next generation 10 GE, 25 GE, and 50 GE switches.
Produkty, Rozwiązania i usługi dla przedsiębiorstw
CloudEngine 6800 Series Data Center Switches
CloudEngine 6800 series switches are next-generation, high-performance, high-density 10GE/25GE access switches designed for data centers and high-end campus networks. They support 100GE and 200GE uplink ports, offer a variety of rich data center features, and incorporate multiple innovative energy-saving technologies to significantly reduce power consumption.
High reliability
M-LAG for millisecond-level link switchover in case of faults.
Intelligence
Significantly simplify operations with intelligent Operations and Maintenance (O&M), proactive reporting of Google Remote Procedure Call (gRPC) high-speed data, proactive detection of network-wide paths, and real-time monitoring of network health status.
Interoperability
Open capabilities allow the switches to interwork with multiple vendors as well as create leading Software-Defined Networking (SDN) networks, evidenced by the Best of ShowNet Award from Interop Tokyo 2016.
Specifications¹
Parameters | CloudEngine 6855-48XS8CQ |
Downlink Ports | 48 x 10 GE SFP+ |
Uplink Ports | 8 x 40/100 GE QSFP28 |
Switching Capacity | 2.56 Tbit/s |
Forwarding Performance | 1200 mpps |
Reliability | LACP BFD for BGP, IS-IS, OSPF, static route, and VXLAN Hardware-based BFD DPFR MoFRR |
O&M | Telemetry Netstream ERSPAN+ IFIT Packet Event |
Data Center Features | 1588v2 MACsec VXLAN routing and bridging BGP-EVPN M-LAG PFC、AI ECN |
Maximum Power Consumption | 298 W |
Power Supply | 600W AC&240V DC 1200W DC |
Operating Voltage | AC:90V to 290V;HVDC: 190V~290V DC: -48V:-38.4V to -72V; +48V DC:+40V DC to +57V DC |
Parameters | CloudEngine 6820H-48S6CQ | CloudEngine 6820-48S6CQ-A |
Downlink Ports | 48 x 10 GE SFP+ | 48 x 10 GE SFP+ |
Uplink Ports | 6 x 40/100 GE QSFP28 | 6 x 40/100 GE QSFP28 |
Switching Capacity | 2.16 Tbit/s | 2.16 Tbit/s |
Forwarding Performance | 470 mpps | 470 mpps |
Buffer | 21 MB | 21 MB |
Reliability | LACP Hardware-based BFD |
LACP Hardware-based BFD |
O&M | Telemetry ERSPAN+ |
Telemetry ERSPAN+ |
Data Center Features | M-LAG ECN |
M-LAG ECN |
Maximum Power Consumption | 282 W | 162 W |
Power Supply | 600W AC&240V DC 1000W -48V DC 1200W HVDC |
600W AC&240V DC 1000W DC 1200W HVDC |
Operating Voltage | AC: 90V~290V DC: -38.4V~-72V 240V HVDC: 190V~290V 380V HVDC: 190V~400V |
AC: 90 V to 290 V DC: –38.4 V to –72 V 240 V HVDC: 190 V to 400 V 380 V HVDC: 190 V to 400 V |
1. This content is applicable only to regions outside the Chinese Mainland. Huawei reserves the right to interpret this content.
Parameters | CloudEngine 6870-48S6CQ-EI-A |
Downlink Ports | 48 x 10 GE SFP+ |
Uplink Ports | 6 x 40/100 GE QSFP28 |
Switching Capacity | 2.16 Tbit/s |
Forwarding Performance | 720 mpps |
Buffer | 8 GB |
Reliability | LACP BFD for BGP, IS-IS, OSPF, static route, and VXLAN |
O&M | Telemetry Netstream sFlow ERSPAN |
Data Center Features | VXLAN routing and bridging BGP EVPN M-LAG DCBX, PFC, and ETS |
Maximum Power Consumption | 394 W |
Power Supply | 600W AC&240V DC 1000W -48V DC 1200W HVDC |
Operating Voltage | AC: 90V~290V DC: -38.4V~-72V 380V HVDC: 190V~400V |
1. This content is applicable only to regions outside the Chinese Mainland. Huawei reserves the right to interpret this content.
Parameters | CloudEngine 6881-48S6CQ | CloudEngine 6881-48T6CQ | CloudEngine 6881H-48S6CQ | CloudEngine 6881H-48T6CQ |
Downlink Ports | 48 x 10 GE SFP+ | 48 x 10 GE Base-T | 48 x 10 GE SFP+ | 48 x 10 GE Base-T |
Uplink Ports | 6 x 40/100 GE QSFP28 | |||
Switching Capacity | 2.16 Tbit/s | |||
Forwarding Performance | 940 mpps | 954 mpps | ||
Buffer | 42 MB | |||
Reliability | LACP BFD for BGP, IS-IS, OSPF, static route, and VXLAN Microsegmentation Hardware-based BFD |
LACP Hardware-based BFD |
||
O&M | Telemetry Netstream sFlow ERSPAN+ |
Telemetry Netstream ERSPAN+ |
||
Data Center Features | VXLAN routing and bridging BGP EVPN M-LAG PFC and ECN |
VXLAN routing and bridging BGP-EVPN M-LAG PTP |
||
Maximum Power Consumption | 349 W | 452 W | 349 W | 452 W |
Power Supply | 600W AC&240V DC 1000W -48V DC 1200W HVDC |
|||
Operating Voltage | AC: 90V~290V DC: -38.4V~-72V 240V HVDC: 190V~290V 380V HVDC: 190V~400V |
AC: 90V~290V DC: -38.4V~-72V 380V HVDC: 190V~400V |
1. This content is applicable only to regions outside the Chinese Mainland. Huawei reserves the right to interpret this content.
Parameters | CloudEngine 6885-48YS8CQ | CloudEngine 6885-48YS8CQ-T | CloudEngine 6885H-48YS8CQ | CloudEngine 6885L-48YS8CQ | CloudEngine 6885-LL-56F |
Downlink Ports | 48 x 10/25 GE SFP28 or 48 x 50 GE SFP56 | 48 x 10/25 GE SFP28 or 48 x 50 GE SFP56 | 48 x 25GE SFP28/48 x 50GE SFP56 | 48 x 10/25 GE SFP28 | 48 x 10/25 GE SFP28 |
Uplink Ports | 8 x 40/100 GE QSFP28 or 8 x 200 GE QSFP56 | 8 x 40/100 GE QSFP28 or 8 x 200 GE QSFP56 | 8 x 100GE QSFP28/8 x 200GE QSFP56 | 8 x 40/100 GE QSFP28 | |
Switching Capacity | 8 Tbit/s | 8 Tbit/s | 8 Tbit/s | 4 Tbit/s | 2.4 Tbit/s |
Forwarding Performance | 1200 mpps | 1200 mpps | 1200 mpps | 1200 mpps | 1200 mpps |
Reliability | LACP BFD for BGP, IS-IS, OSPF, static route, and VXLAN Hardware-based BFD DPFR MoFRR |
LACP BFD for BGP, IS-IS, OSPF, static route, and VXLAN Hardware-based BFD DPFR MoFRR |
LACP BFD for BGP, IS-IS, OSPF, static route, and VXLAN Hardware-based BFD DPFR MoFRR |
LACP BFD for BGP, IS-IS, OSPF, static route, and VXLAN Hardware-based BFD DPFR MoFRR DPCF |
LACP BFD for BGP, IS-IS, OSPF, static route MoFRR |
O&M | Telemetry Netstream ERSPAN+ IFIT Packet Event |
Telemetry Netstream ERSPAN+ IFIT Packet Event |
Telemetry Netstream ERSPAN+ IFIT Packet Event |
Telemetry Netstream ERSPAN+ IFIT Packet Event |
Telemetry Netstream ERSPAN+ Edge intelligence Packet Event |
Data Center Features | 1588v2 MACsec VXLAN routing and bridging BGP-EVPN M-LAG PFC、AI ECN |
TPM 1588v2 MACsec VXLAN routing and bridging BGP-EVPN M-LAG PFC、AI ECN |
1588v2 MACsec VXLAN routing and bridging BGP-EVPN M-LAG PFC、AI ECN |
1588v2 VXLAN routing and bridging BGP-EVPN M-LAG PFC、AI ECN |
Minimum L2/L3 forwarding delay: 320 ns to 350 ns 1588v2 M-LAG PFC、AI ECN |
Maximum Power Consumption | 326 W | 326 W | 147 W (100% traffic load, copper cables on 24 x 25G + 4 x 100G ports, normal temperature, dual AC power modules) 166 W (100% traffic load, short-distance optical modules on 24 x 25G + 4 x 100G ports, normal temperature, dual AC power modules) |
48x25G+8x100G: 197 W (100% load, all-port short-distance optical modules, normal temperature, dual AC power supplies) 313 W (100% load, full-port long-distance optical module, high temperature, dual AC power supplies) |
176 W |
Power Supply | 600W AC&240V DC 1200W DC |
600W AC&240V DC 1200W DC |
600 W AC&240 V DC 1200 W DC |
600W AC&240V DC 1200W DC 400W DC |
600W AC&240V DC 1200W DC |
Operating Voltage | AC:90V to 290V;HVDC: 190V~290V DC: -48V:-38.4V to -72V; +48V DC:+40V DC to +57V DC |
AC:90V to 290V;HVDC: 190V~290V DC: -48V:-38.4V to -72V; +48V DC:+40V DC to +57V DC |
AC:90V to 290V;HVDC: 190V~290V DC: -48V:-38.4V to -72V; +48V DC:+40V DC to +57V DC |
600 W AC&240 V DC power module: 90 V AC to 290 V AC, 45/65 Hz; 240 V DC 1200 W DC power module: –48 V DC to –60 V DC; +48 V DC 400 W DC power module: –48 V DC to –60 V DC; +48 V DC |
AC:90V to 290V;HVDC: 190V~290V DC: -48V:-38.4V to -72V; +48V DC:+40V DC to +57V DC |
Parameters | CloudEngine 6863-48S6CQ | CloudEngine 6863E-48S6CQ | CloudEngine 6863H-48S6CQ |
Downlink Ports | 48 x 10/25 GE SFP28 | 48 x 10/25 GE SFP28 | 48 x 10/25 GE SFP28 |
Uplink Ports | 6 x 40/100 GE QSFP28 | 6 x 40/100 GE QSFP28 | 6 x 40/100 GE QSFP28 |
Switching Capacity | 3.6 Tbit/s | 3.6 Tbit/s | 3.6 Tbit/s |
Forwarding Performance | 940 mpps | 940 mpps | 954 mpps |
Buffer | 42 MB | 42 MB | 42 MB |
Reliability | LACP Microsegmentation Hardware-based BFD |
LACP Microsegmentation Hardware-based BFD |
LACP Hardware-based BFD |
O&M | Telemetry Netstream sFlow ERSPAN+ |
Telemetry Netstream sFlow ERSPAN+ |
Telemetry Netstream ERSPAN+ |
Data Center Features | VXLAN routing and bridging BGP EVPN M-LAG PFC and ECN |
VXLAN routing and bridging BGP EVPN M-LAG PFC and ECN |
VXLAN routing and bridging BGP-EVPN M-LAG PTP |
Maximum Power Consumption | 349 W | 384 W | 384 W |
Power Supply | 600W AC&240V DC 1000W -48V DC 1200W HVDC |
600W AC&240V DC 1000W -48V DC 1200W HVDC |
600W AC&240V DC 1000W -48V DC 1200W HVDC |
Operating Voltage | AC: 90V~290V DC: -38.4V~-72V 240V HVDC: 190V~290V 380V HVDC: 190V~400V |
AC: 90V~290V DC: -38.4V~-72V 240V HVDC: 190V~290V 380V HVDC: 190V~400V |
AC: 90V~290V DC: -38.4V~-72V 380V HVDC: 190V~400V |
1. This content is applicable only to regions outside the Chinese Mainland. Huawei reserves the right to interpret this content.
Parameters | CloudEngine 6860-HAM | CloudEngine 6866-48S8CQ-P |
Downlink Ports | 48 x 10/25 GE SFP28 or 48 x 50 GE SFP56 | 48 x 10/25 GE SFP28 or 48 x 50 GE SFP56 |
Uplink Ports | 8 x 40/100 GE QSFP28 or 8 x 200 GE QSFP56 | 8 x 40/100 GE QSFP28 or 8 x 200 GE QSFP56 |
Switching Capacity | 8 Tbit/s | 8 Tbit/s |
Forwarding Performance | 2175 mpps | 2175 mpps |
Buffer | 64 MB | 64 MB |
Reliability | LACP Hardware-based BFD |
LACP Hardware-based BFD |
O&M | Telemetry Netstream ERSPAN+ AnyFlow Intelligent Traffic Analysis Packet Event |
Telemetry Netstream ERSPAN+ AnyFlow Intelligent Traffic Analysis Packet Event |
Data Center Features | 32k multicast entries, MoFRR VXLAN routing and bridging BGP EVPN M-LAG 3.0 |
VXLAN routing and bridging BGP EVPN M-LAG |
Intelligent and Lossless Network | AI ECN PFC Deadlock Prevention ECN Overlay iQCN |
|
Maximum Power Consumption | 48 x 50 GE + 8 x 200 GE: 619 W 48 x 25 GE + 8 x 100 GE: 544 W |
48 x 50 GE + 8 x 200 GE: 619 W 48 x 25 GE + 8 x 100 GE: 544 W |
Power Supply | 600W AC&240V DC 1000W -48V DC 1200W HVDC |
600W AC&240V DC 1000W -48V DC 1200W HVDC |
Operating Voltage | AC: 90V~290V DC: -38.4V~-72V 240V HVDC: 190V~290V 380V HVDC: 190V~400V |
AC: 90V~290V DC: -38.4V~-72V 240V HVDC: 190V~290V 380V HVDC: 190V~400V |
1. This content is applicable only to regions outside Chinese Mainland. Huawei reserves the right to interpret this content.
Resources
Technical Support