NetCol8000-A In-Room Air Cooled Smart Cooling Products

In-room, air cooled NetCol8000-A smart cooling products are suitable for small- and medium-sized Data Centers (DCs), power distribution rooms, and small computer rooms.

Configured with a high-efficiency DC inverter compressor, Electronically Commutated (EC) fan, and Electronic Expansion Valve (EEV) for on-demand cooling, NetCol8000-A provides energy savings of more than 30% at partial load, compared to fixed-frequency systems, helping build next-generation, green data centers.

Offering stepless capacity with high efficiency at partial load, plus operation without heated water, NetCol8000-A offers energy savings of more than 95% compared to electrode humidifiers.

The NetCol series of cooling products have been deployed around the world, and are used in carrier, Internet Service Provider (ISP), government, finance, transportation, energy, medical, and education sectors.

Huawei

Specifications


Unit Model NetCol8000-A013U
Air Discharge Direction Upflow
Total Cooling Capacity¹ 13 kW
Sensible Cooling Capacity 11.7 kW
Air Volume 3600 m3/h
Power Supply Voltage 380–415 V, 3 phase, 50 (60) Hz
Refrigerant R410A
Heating Capacity (Optional) 4 kW
Humidifier Capacity (Optional) 3 kg/h
Dimensions (H x W x D) 1886 x 800 x 664 mm
Net Weight² 141 (153) kg

Notice:

1. Nominal cooling condition: 24°C return air dry bulb temperature, 50% relative humidity, 35°C outdoor temperature.

2. The number in parenthesis is applicable to units with an electric heater and humidifier.

Unit Model NetCol8000-A045D/U NetCol8000-A090D
Air Discharge Direction D: Downflow; U: Upflow
Total Cooling Capacity¹ 45 kW 90 kW
Sensible Cooling Capacity 45 kW 90 kW
Air Volume 11,250 m3/h 22,500 m3/h
Power Supply 380/400/415 V, 3 phase, 50/60 Hz
Heating Capacity 6 kW 12 kW
Humidifier Capacity 6 kg/h 10 kg/h
Full Load Current² 36 (40) A 72 (80) A
Dimensions (H x W x D) 2000 x 900 x 900 mm 2000 x 1800 mm x 1000 mm
Net Weight 355 kg 643 kg

Notice:

1. Nominal cooling condition: 35°C return air dry bulb temperature, 26% relative humidity, 35°C outdoor temperature.

2. The numbers in parentheses are applicable to indoor units with an electric heater and humidifier (optional).

For Partners

Amennyiben már partnerünk, kérjük kattintson ide annak érdekében, hogy több marketing anyag váljon elérhetővé az Ön számára.
Kattintson ide amennyiben a Partner Zóna meglátogatása, a tudakozódási státusz ellenőrzése, a rendelések menedzselése, segítség igénylése vagy a Huawei Partnerekről való több információ elérése az igénye.