This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Search
  • OceanStor Pacific 9920 Scale-out Storage

    OceanStor Pacific 9920
    Scale-out Storage

    Meet the needs of millions of VMs with a single system.

  • Overview
  • Specifications
  • Resources
OceanStor Pacific 9920 Scale-out Storage
OceanStor Pacific 9920 Scale-out Storage

OceanStor Pacific 9920 Scale-out Storage

OceanStor Pacific 9920 is a new, all-flash, Solid-State Drive (SSD) scale-out storage system that houses one node per 2U chassis. It offers outstanding performance and flexible component configurations, meeting the access requirements of a wide range of structured and unstructured data workloads.

Featuring FlashLink and Artificial Intelligence (AI) Fabric network acceleration, OceanStor Pacific 9920 enables a single system to meet the performance needs of millions of Virtual Machines (VMs). In addition, flexible data redundancy ratios are available and the system can work with OceanStor Pacific 9540 to build a tiered storage solution. As such, OceanStor Pacific 9920 provides efficient data access services for diverse scenarios, from virtualization and cloud resource pools to databases, High Performance Computing (HPC), AI applications, and big data analytics.

Specifications

Product Model OceanStor Pacific 9920
Scenario Unstructured Data Structured Data
System Architecture Fully symmetric scale-out architecture Fully symmetric scale-out architecture
Storage Access Protocol NFS, SMB, POSIX, MPI-IO, HDFS, Amazon S3, and FTP SCSI, iSCSI, and OpenStack Cinder
Raw Capacity per Chassis 23.04 TB ~ 768 TB 7.68 TB ~ 768 TB
Height per Chassis 2U 2U
Number of Nodes per Chassis 1 1
Max. Number of Primary Storage Disks per Node 25 25
Primary Storage Disk Type Palm-sized NVMe SSDs Palm-sized NVMe SSDs
Processors per Node 2 x Huawei Kunpeng 920 Processors 2 x Kunpeng 920 processors
Max. Memory per Node 512 GB 512 GB
Number of System Disks per Node 2 x 480 GB SATA SSDs 2 x 480 GB SATA SSDs
Front-End Service Network Type*
• 25GE or 100GE TCP/IP
• 100GE RoCE
• 100Gb/s or 200Gb/s InfiniBand
• 10 GE or 25 GE TCP/IP
• 25 GE or 100 GE RoCE
• 100 Gbit/s InfiniBand
Storage Network Type
• 100GE TCP/IP
• 25GE or 100GE RoCE
• 100Gb/s or 200Gb/s InfiniBand
• 10 GE or 25 GE TCP/IP
• 25 GE or 100 GE RoCE
• 100 Gbit/s InfiniBand
Data Redundancy Protection Mechanism EC: N + M (M is 2, 3, or 4)
• EC: N + M (M is 2, 3, or 4)
• Multi-copy: 3-copy mode
Data Self-Healing Automatic concurrent data reconstruction at 2 TB per hour Automatic concurrent data reconstruction at 4 TB per hour
Key Features
• Elastic EC
• SmartQuota
• SmartTier
• SmartQoS
• SmartEqualizer
• SmartMulti-Tenant
• SmartEncryption
• SmartAuditlog
• HyperLock(WORM)
• HyperSnap
• HyperReplication(A)
• SmartIndexing
• Recycle Bin
• SmartInterworking
• DIF
• Object Versioning*
• SmartTakeover*
• SmartCompression
• HyperGeoMetro*
• HyperGeoEC*
• SmartCache
• SmartSync
• SmartThin
• SmartDedupe & SmartCompression
• SmartQoS
• SmartEncryption
• SmartAuditlog
• HyperSnap
• HyperClone
• HyperMetro
• HyperReplication(S)
• HyperReplication(A)
• MultiPool
• DIF
• SmartMove
Storage Management Software DeviceManager and eService DeviceManager and eService
Chassis Dimensions (H x W x D) 86.1 mm x 447 mm x 830 mm 86.1 mm x 447 mm x 830 mm
Max. Weight per Chassis (with Disks) ≤ 35 kg ≤ 35 kg
Operating Temperature 5°C to 35°C 5°C to 35°C
Operating Humidity 8% RH to 90% RH (non-condensing) 5% to 90% RH (non-condensing)

*Please contact Huawei sales representatives for more information.

TOP