Huawei OptiXaccess EA5801E-GP04
Compact and Low-density Box-shaped OLT.
This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>
Produits, solutions et services pour les entreprises
Lightweight and small size
Dual power supplies, high reliability
Easy installation and flexible deployment
Specifications
Parameters | Huawei OptiXaccess EA5801E-GP04 |
Dimensions (W x D x H) (mm) | Excluding mounting ears: 442 x 220 x 43.6 Including IEC mounting ears: 482.6 x 220 x 43.6 Including ETSI mounting ears: 535 x 220 x 43.6 |
Maximum fully-loaded weight (DC) | 5kg |
Power supply mode | AC power supply (dual backup) |
Working voltage range | AC power supply: 100–240 V |
Rated voltage | AC power supply: 110 V/220 V |
Maximum input current | AC power supply: 2.5 A |
Ambient temperature | –40°C to +65°C The device can start up at a lowest temperature of –25°C. NOTE The +65°C temperature refers to the highest temperature measured at the air intake vent of a service subrack. |
Ambient humidity | 5%–95% RH |
Atmospheric pressure | 70–106 kPa |
Altitude | < 4000 m. The air density varies with the altitude and will affect the heat dissipation of a device. Therefore, the working environment temperature of the device varies with the altitude. |
System switching capacity | 95 Gbit/s |
MAC addresses | 32768 |
Access ONT | 256 |
IPv4 routing table | 8192 |
IPv6 routing table | 4096 |
ARP table | 16384 |
Bit error rate (BER) in full load | A BER smaller than 10 e-10 for a port that transmits data in full load |
10GE/GE upstream ports | 4 |
Service ports | 4 GPON |
Power consumption | AC power supply: • Static Power Consumption: 47 W • Typical Power Consumption: 58 W • Maximum Power Consumption: 100 W NOTE The power consumption of a product is tested in the following conditions: • Static power consumption: 25°C, no optical module in optical ports, and no service. • Typical power consumption: 25°C, 4 x 10GE(10kM) upstream ports, 4 x GPON(CLASS C+) ports on the user side, full services, and maximum traffic. • Maximum power consumption: 65°C, 4 x 10GE(10kM) upstream ports, 4 x GPON(CLASS C+) ports on the user side, full services, and maximum traffic. |