Huawei OptiXaccess EA5801E-GP08
A compact box-shaped OLT.
Enterprise products, solutions & services
Huawei OptiXaccess EA5801E-GP08
The OptiXaccess EA5801E-GP08 Optical Line Terminal (OLT) provides Gigabyte Passive Optical Networks (GPON) access, and supports Fiber To The Home (FTTH), Fiber To The Office (FTTO), and Fiber To The Machine (FTTM) solutions. It carries all services over one fiber network, simplifying network architecture and reducing Operating Expenditure (OPEX).
Lightweight and Small
High Reliability
Easy Installation and Flexible Deployment
Specifications
Parameters | Huawei OptiXaccess EA5801E-GP08 |
Dimensions (H x W x D) | Excluding mounting ears: 43.6 x 442 x 220 mm Including IEC Mounting Ears: 43.6 x 482.6 x 220 mm Including ETSI mounting ears: 43.6 x 535 x 220 mm |
Maximum Fully-loaded Weight (DC) | 5 kg |
Power Supply Mode | DC power supply (dual backup) AC power supply (dual backup) |
Working Voltage Range | DC power supply: –38.4 V to –72 V AC power supply: 100–240 V |
Rated Voltage | DC power supply: –48 V/–60 V AC power supply: 110 V/220 V |
Maximum Input Current | DC power supply: 6 A AC power supply: 2.5 A |
Ambient Temperature | –40°C to +65°C The device can start up at a lowest temperature of –25°C. Note: The +65°C temperature refers to the highest temperature measured at the air intake vent of a service subrack. |
Ambient Humidity | 5%–95% RH |
Atmospheric Pressure | 70–106 kPa |
Altitude | Below 4000 m Note: The air density varies with the altitude and will affect the heat dissipation of a device, so the working environment temperature of the device varies with the altitude. |
System Switching Capacity | Below 4000 m Note: The air density varies with the altitude, which affects the heat dissipation capability of devices, so the operating temperature of the device changes with the altitude. |
MAC Addresses | 32768 |
Access ONT | 256 |
IPv4 Routing Table | 8192 |
IPv6 Routing Table | 4096 |
ARP Table | 16384 |
Bit Error Rate (BER) in Full Load | A BER smaller than 10 e-10 for a port that transmits data in full load |
10 GE/GE upstream ports | 4 |
Service ports | 8 GPON |
Power Consumption | Static Power Consumption: DC power supply: 50 W AC power supply: 51 W Typical Power Consumption: DC power supply: 85 W AC power supply: 88 W Maximum Power Consumption: DC power supply: 90 W AC power supply: 94 W Note: The power consumption of the device is calculated based on the following conditions: Static power consumption: 25°C, no optical module in any optical port, and no service running. Typical power consumption: 25°C, 4 x 10 GE upstream transmission, 16 x GPON ports, full service configuration, and full traffic. Maximum power consumption: 50°C, 4 x 10 GE upstream transmission, 16 x GPON ports, full service configuration, and full traffic. |